[FHK]
Fuji Hokuroku Flux Observation Site
  • Site Description
  • Observation
  • Researchers
  • Note
  • Eddy Correlation Method

    System Open- and closed-path systems (CO2 flux, latent heat flux)
    Wind speed Three-dimensional sonic anemometer-thermometer (DA600-3TV (Probe TR-62AX), KAIJO)
    Air temperature Three-dimensional sonic anemometer-thermometer (DA600-3TV (Probe TR-62AX), KAIJO)
    Platinum resistance thermometer and capacitive hygrometer (HMP45A, Vaisala)
    Water Vapor Open- and Closed-path CO2/H2O analyzers (LI-7500 and LI-6262, LI-COR)
    Platinum resistance thermometer and capacitive hygrometer (HMP45A, Vaisala)
    CO2 Open- and Closed-path CO2/H2O analyzers (LI-7500 and LI-6262, LI-COR)
    Measurement height 35m
    Sampling frequency 10 Hz
    Averaging time 30 min
    Data logger DRM3b, TEAC, Japan
    Data storage MO
    Original data (Raw data or statistics) Raw data

    Meteorology

    Observation items Levels / Depth Instrument
    Global solar radiation (incoming) 32m
    2m (five points)
    32, 2 (two points) m
    Pyranometer (MS-402F, Eko, Japan)
    Pyranometer (MS-601, Eko, Japan)
    Radiometer (MR-50, Eko, Japan)
    Global solar radiation (outgoing) 32, 2 (two points) m Radiometer (MR-50, Eko, Japan)
    Long-wave radiation (incoming) 32, 2 (two points) m Radiometer (MR-50, Eko, Japan)
    Long-wave radiation (outgoing) 32, 2 (two points) m Radiometer (MR-50, Eko, Japan)
    Net radiation 32, 2 (two points) m Radiometer (MR-50, Eko, Japan)
    PPFD (incoming) 32, 2 (five points) m Quantum sensor (LI-190S, LI-COR, Jan.2006-Mar.2007), (ML-020P, Eko, Japan, Mar.2007-)
    PPFD (outgoing) 30, 2 (three points) m Quantum sensor (LI-190S, LI-COR, Jan.2006-Mar.2007), (ML-020P, Eko, Japan, Mar.2007-)
    Direct/diffuse radiation 32m Shadow band (PRB-100, PREDE, Japan)
    Direct/diffuse PPFD - -
    Air temperature 32,27,16,10,4.5,2,1,0.5m Platinum resistance thermometer and capacitive hygrometer (HMP-45D, Vaisala)
    Humidity 32,27,16,10,4.5,2,1,0.5m Platinum resistance thermometer and capacitive hygrometer (HMP-45D, Vaisala)
    Soil temperature 0, 0.02, 0.05m (three points),0.15, 0.3, 0.6, 1 m Platinum resistance thermometer (C-PTWP, Climatec, Japan)
    Soil heat flux 0.02m (three points) Heat flux plate (HF-01, REBS)
    Soil water content 0m (three points),
    0.1, 0.2m (two points
    TDR sensor (CS616, Campbell)
    Wind speed 32,27,16,10,4.5,2m Sonic anemometer (MA-130A, Eko, Japan, Jan.2006-Mar.2007), (PGWS-100-3, GILL, Apr.2007-)
    Wind direction 32,27,16,10,4.5,2m Sonic anemometer (MA-130A, Eko, Japan, Jan.2006-Mar.2007), (PGWS-100-3, GILL, Apr.2007-)
    Barometric pressure 1.5m Barometer (PTB210, Vaisala)
    Precipitation 32m Tipping-bucket rainguage with heater (CYG-52202, R. M. Young)
    CO2 concentration 32, 27, 22,16,10,4.5,2,1 m CO2/H2O analyzers (LI-6262, LI-COR)
    Snow depth 2m Sonic ranging sensor (SR50, Campbell)
    Spectral radiation (incoming) 32m Spectroradiometer (MS-700, Eko, Japan)
    Spectral radiation (outgoing) 32m Spectroradiometer (MS-700, Eko, Japan)

    Other

    Soil respiration Continuous (automated chambers)
    Photosynthesis Occasionally
    Ecological Investigation Tree heights, stand density, diameter, biomass, LAI
    Phenology Continuous (photos)